MMS-H - Enclosed Manual Motor Starter with High Breaking Trip

Rugged Construction. Superior Protection.

MMS-H - Enclosed Manual Motor Starter with High Breaking Trip

Rugged Construction. Superior Protection.

MMS-H - Enclosed Manual Motor Starter with High Breaking Trip

Rugged Construction. Superior Protection.

  • 1Ø & 3Ø, 1/10~30HP, 115~600VAC
The Enclosed Manual Motor Stater includes a high break thermal magnetic or magnetic trip only lockable disconnect in a heavy-duty impact-resistant plastic case with an IP65 rating. This UL listed manual motor control provides motor overload and motor circuit protection in one package without a separate circuit breaker or fuses. Optional auxillary switches, magnetic trip alarm switch, any trip alarm switch, shunt release, and undervoltage release available.
  • Rugged Construction with Standard Handle Lock-out
  • With a heavy-duty impact-resistant plastic case. IP65 rating. (UL Type 4/4X pending)
  • Standard rotary switch includes easy provision for padlock/tag-out at no extra charge.
  • Superior Protection
  • UL listed manual motor control provides motor overload and motor circuit protection in one package - no separate circuit breaker or fuses required
  • Both models are rated up to 100,000 Amps interrupting capacity - ensuring maximum compatibility and coordination with existing electrical installations.
  • Meet UL Type E ratings for group motor installation with no additional branch circuit breaker or fuses required
  • Front auxiliary switch
  • Side auxiliary switch
  • Magnetic trip alarm switch
  • Any trip alarm switch
  • Shunt release
  • Undervoltage release
  • Undervoltage release with auxiliary (2NO)

Specs & Documents

Be the first to review this product

Availability: In stock

From: $153.01

To: $1,000.00

Price as configured: $0.00

Please select product spec for MMS-H - Enclosed Manual Motor Starter with High Breaking Trip

Don't worry, you can change these later on.

A disconnect provides short circuit protection, and a means of disconnecting power to safely service the application. Disconnects can be locked/tagged out in the open (off) position to ensure the system isn’t energized during service.

Use a NEMA 1 enclosure when panels are installed in clean, indoor environment. NEMA 3R is a rainproof enclosure meant for outdoor installations.

Check the motor nameplate to find your motor's rated Horsepower

Enter single or three phase based on the incoming power distribution system.

Check the voltage on your motor nameplate. This should be consistent with the supply voltage from your power distribution system.

Check the motor nameplate to find the FLA of the motor. (SFA for submersible motors)

  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes

Price as configured: $0.00

  • Please select enter value.