Menu

BAS-1P - 1Ø Building Automation Starter

One Phase. One Solution.

BAS-1P - 1Ø Building Automation Starter

One Phase. One Solution.

BAS-1P - 1Ø Building Automation Starter

One Phase. One Solution.

  • 1Ø, 110V, 1/10 - 1HP
  • 1Ø, 240V, 1/10 - 1HP
The BAS-1P protects single phase motors with an adjustable 1-16A class 10 electronic overload. It includes features like run status verification, a concealed Hand/Auto switch, lockable on/off switch, and system override mode (smoke purge). All of this in a compact design that installs on a single junction box.
  • On/Off Disconnect Switch with Recessed Hand/Auto Modes
  • Concealed Hand/Auto switch discourages tampering
  • Lockable motor-rated On/Off switch meets safety regulations
  • Meets NEC motor service disconnect requirements when properly installed
  • LED indicator lights for power, run and fault
  • Run Status Verification
  • Integrated current sensing confirms motor operational status
  • Quickly and accurately pinpoint malfunctioning equipment
  • Voltage & Dry Inputs for Auto Run Command
  • Wire directly from the automation system to the starter, no interposing relays necessary
  • Save on installation costs and increase reliability.
  • System Override Mode (Fireman’s, Occupancy or Manual)
  • Initiates smoke purge sequence during emergency situations for safety and code compliance or use for occupancy sensor run input (dry contact)
  • Wide Range Class 10 Electronic Overload
  • Prevents ordering confusion and eliminates call backs due to mis-sized heaters
  • Advanced protective features including anti-cycling, manual/auto reset, etc.
  • Standard Single Gang Box Installation
  • Easy to install in any location
  • Surface or flush mount capability
  • High Reliability
  • Heavy duty motor-rated switch and control relay
  • No thermal elements to fail
  • All units include a 5-Year warranty
  • UL 508 Listed
  • UL Type 1 enclosed
  • UL Type 4 and 4X (contact factory)
  • Automatic overload trip reset

Specs & Documents

Be the first to review this product

Availability: In stock

From: $180.00

To: $1,025.00

Price as configured: $0.00

Please select product spec for BAS-1P - 1Ø Building Automation Starter

Don't worry, you can change these later on.

A disconnect provides short circuit protection, and a means of disconnecting power to safely service the application. Disconnects can be locked/tagged out in the open (off) position to ensure the system isn’t energized during service.

Use a NEMA 1 enclosure when panels are installed in clean, indoor environment. NEMA 3R is a rainproof enclosure meant for outdoor installations.

Check the motor nameplate to find your motor's rated Horsepower

Enter single or three phase based on the incoming power distribution system.

Check the voltage on your motor nameplate. This should be consistent with the supply voltage from your power distribution system.

Check the motor nameplate to find the FLA of the motor. (SFA for submersible motors)

  • No Yes

* Required Fields

Price as configured: $0.00

  • Please select enter value.
Available in Stores