Starters

Energy Management Starter

EMS - Energy Management Starter

The Most Intelligent Starter

  • 1Ø, 120 ~ 230V, 1/10-25HP
  • 3Ø, 200 ~ 600V, 1/2-300HP
Power metering, optional BACnet or Modbus communications, and an intuitive interface allow the EMS to integrate seamlessly with building automation systems. By combining starter operation with controls, you extend equipment life and save energy. Installation is cost-effective thanks to integrated sensing and control points.
Building Automation Starter

BAS - Building Automation Starter

Smarter and more versatile than ever

  • 3Ø, 200~600V, 1/2-30HP
Equipped with advanced I/O including Fireman’s Override and damper control, the BAS was designed from the ground up for easy integration with automation systems. With a 200 to 600V input and 1-40A adjustable overload, the BAS is the right starter for almost any job.
Standard Automation Starter

SAS - Standard Automation Starter

Advanced Protection, Incredible Value

  • 3Ø, 200~600V, 1/2-30HP
  • 1Ø, 230V, 1/10-7.5HP
Like the BAS, the SAS accepts 200 to 600VAC incoming power, making it a plug and play device. The 1-40A electronic overload ensures you will have the right starter for the job, and Smartstart revolutionary technology protects motors from potentially harmful start-up conditions. The SAS is automation compatible.
1Ø Building Automation Starter

BAS-1P - 1Ø Building Automation Starter

One Phase. One Solution.

  • 1Ø, 110V, 1/10 - 1HP
  • 1Ø, 240V, 1/10 - 1HP
The BAS-1P protects single phase motors with an adjustable 1-16A class 10 electronic overload. It includes features like run status verification, a concealed Hand/Auto switch, lockable on/off switch, and system override mode (smoke purge). All of this in a compact design that installs on a single junction box.
Description
Power metering, optional BACnet or Modbus communications, and an intuitive interface allow the EMS to integrate seamlessly with building automation systems. By combining starter operation with controls, you extend equipment life and save energy. Installation is cost-effective thanks to integrated sensing and control points.
Equipped with advanced I/O including Fireman’s Override and damper control, the BAS was designed from the ground up for easy integration with automation systems. With a 200 to 600V input and 1-40A adjustable overload, the BAS is the right starter for almost any job.
Like the BAS, the SAS accepts 200 to 600VAC incoming power, making it a plug and play device. The 1-40A electronic overload ensures you will have the right starter for the job, and Smartstart revolutionary technology protects motors from potentially harmful start-up conditions. The SAS is automation compatible.
The BAS-1P protects single phase motors with an adjustable 1-16A class 10 electronic overload. It includes features like run status verification, a concealed Hand/Auto switch, lockable on/off switch, and system override mode (smoke purge). All of this in a compact design that installs on a single junction box.
Ranges

1Ø, 120 ~ 230V, 1/10-25HP
3Ø, 200 ~ 600V, 1/2-300HP

3Ø, 200~600V, 1/2-30HP

3Ø, 200~600V, 1/2-30HP
1Ø, 230V, 1/10-7.5HP

1Ø, 110V, 1/10 - 1HP
1Ø, 240V, 1/10 - 1HP

User Interface

HOA keypad with LEDs & LCD display

HOA keypad with LEDs

HOA keypad with LEDs

On/Off switch, recessed Hand-Auto mode switch, LEDs

Overload Type

Wide range electronic overload (class 5-30)

Wide range electronic overload
(class 10/20)

Wide range electronic overload (class 10)

Wide range electronic overload (class 10)

Standard
  • Voltage/dry contact auto run inputs
  • Proof of flow (true power) output
  • Fault relay output
  • Fireman’s override input
  • Shut down input
  • Permissive auto input
  • Damper control
  • Voltage/dry contact auto run inputs
  • Proof of flow current status
  • Fault relay output
  • Fireman’s override input
  • Shut down input
  • Permissive auto input
  • Damper control
  • Voltage/dry contact auto run inputs
  • Proof of flow current status
  • Current status (On/Off)
Options
  • Motor Circuit Protection disconnect
  • UL Type 1 and 3R enclosures
  • UL Type 4 and 4X (contact factory)
  • Metering - Analog kW, Pulse kWh
  • Metering - BACnet
  • BACnet communications
  • Modbus RTU communications
  • Over/Under voltage
  • Over/Under power (belt loss protection)
  • Ground fault protection
  • Backspin/on delay timers
  • Ethernet Fault Logging
  • 120V Damper Control in lieu of 24V Standard
  • Motor Circuit Protection disconnect
  • UL Type 1 and 3R enclosures
  • UL Type 4 and 4X (contact factory)
  • Motor Circuit Protection disconnect
  • UL Type 1 and 3R enclosures
  • UL Type 4 and 4X (contact factory)