Menu

Enclosed P-Drive - P-Series Enclosed Variable Frequency Drive

Enclosed P-Drive - P-Series Enclosed Variable Frequency Drive

Enclosed P-Drive - P-Series Enclosed Variable Frequency Drive

  • 1-40HP (200~230VAC), 1-400HP (380~480VAC), 3Ø
Enclosed Drive packages offer our P Series VFD in Nema 3R and 12 enclosure designed to withstand harsh environments. Additional application-specific protective option include surge arrestors, line reactors, load reactors, and dV/dT filters. The P Series VFD has a quick and easy setup with application based commissioning through the FastApp firmware. Other features include advanced PID control, multi-motor function, automatic energy savings mode, sleep and wake function, flying start protection, flux braking algorithm, pre-heater function, automatic carrier frequency,selectable V/F, sensorless vector control, long-life condensor, and much more!
  • Designed to Withstand Harsh Environments
  • UL Type 3R or 12 packaging for outdoor and/or wash down applications
  • Additional application-specific protective options
  • - Lightning/Surge Arrestor
  • - Line Reactors
  • - Load Reactors
  • - dV/dT Filter
  • Rainproof UL Type 3R enclosure reduces thermal absorption with white, solar reflective finish and filtered cooling fans
  • Standard enclosed VFD package is rated for 92° F outside temperature, non-direct sunlight
  • Attain up to 110° F outside temperature, non-direct sunlight by derating VFD
  • Functionality
  • A single VFD has the capability to control up to four additional motors reducing the need for additional controls
  • Sleep mode reduces energy consumption by stopping motors during periods of low demand
  • Flexible sensor inputs accept 0-10VDC and 4-20mA analog signals
  • VFD provides additional 12VDC and 24VDC power for sensors
  • PID control and Pre-PID mode with time delay reduces water hammer and cavitation while providing precise system control
  • Dual PID control for external PID control of a secondary system
  • Line reactor
  • Output reactor/filter
  • UL Type 3R and 12
  • UL Type 4 and 4X (contact factory)
  • Run pilot light (Green standard)
  • Fault pilot light (Red standard)
  • Hand/Off/Auto switch
  • Door mounted speed potentiometer
  • Door mounted keypad
  • Door mounted keypad with Type 4X cover

Product videos

Product videos
Play

Be the first to review this product

Availability: In stock

From: $1,000.00

To: $124,269.00

Price as configured: $0.00

Please select product spec for Enclosed P-Drive - P-Series Enclosed Variable Frequency Drive

Don't worry, you can change these later on.

A disconnect provides short circuit protection, and a means of disconnecting power to safely service the application. Disconnects can be locked/tagged out in the open (off) position to ensure the system isn’t energized during service.

Use a NEMA 1 enclosure when panels are installed in clean, indoor environment. NEMA 3R is a rainproof enclosure meant for outdoor installations.

Check the motor nameplate to find your motor's rated Horsepower

Enter single or three phase based on the incoming power distribution system.

Check the voltage on your motor nameplate. This should be consistent with the supply voltage from your power distribution system.

Check the motor nameplate to find the FLA of the motor. (SFA for submersible motors)

  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes

* Required Fields

Price as configured: $0.00

  • Please select enter value.