EMB-3 Contactor - Energy Management Bypass

Advanced Protection & Metering in VFD or Bypass Mode

EMB-3 Contactor - Energy Management Bypass

Advanced Protection & Metering in VFD or Bypass Mode

EMB-3 Contactor - Energy Management Bypass

Advanced Protection & Metering in VFD or Bypass Mode

  • 3Ø, 1-40HP (200-230VAC), 1-400HP (380-480VAC)
The Energy Management Bypass uses a reliable bypass starter with a revolutionary electronic overload to give all of the protection, monitoring and control of your motor a VFD would. The VFD and bypass offer ANSI grade power meter, advanced motor protection, and damper control.
  • General Features
  • Energy Management Bypass (EMB) features
  • ANSI grade power meter in bypass and VFD mode
  • Phase loss, phase unbalance, UL 1053 ground fault, and OV/UV protection for VFD and bypass
  • Integrated BACnet control and keypad for bypass
  • Fireman’s override/smoke purge ready
  • Belt loss protection and fault alarm in bypass mode
  • Damper and valve control through EM-Bypass and VFD
  • Dual action 3% input line reactor - harmonic mitigation for IEEE 519 and transient voltage spike protection
  • Input MCP disconnect
  • Wide range of design options
  • Door mounted control options for manual speed pot, LED lights and more
  • Compact vertical design preserves wall space (UL Type 1)
  • Weatherproof enclosures are powder coated white to reflect heat (UL Type 3R)
  • Optional Electronic Overload for full phase protection in bypass mode
  • Panel space heaters available for ambient temperatures below -10oC~14oF (UL Type 3R)
  • Enclosure options for any environment
  • A variety of NEMA rated enclosures to meet application requirements (Stainless, fiberglass, watertight, etc.)
  • Derated NEMA 3R for 110°F ambient temperature rating in white powdercoat, weatherproof enclosure
  • AC cooled VFD options for extreme heat installations
  • P Series VFD Specific Features
  • New FastApp™
  • Firmware makes setup a snap
  • Application based commissioning allows parameters to be automatically set based on industry standards
  • Applications: Basic, circulating pump, supply fan, submersible pump & more
  • Selectable units include PSI, °F, °C, inWC, inM, Bar, mBar, Pa, kPa
  • Belt loss protection
  • Other standard VFD features
  • Space Vector Pulse Width Modulation control for efficiency and long motor life
  • Advanced PID control (Pre-PID and Dual PID)
  • Multi-motor function controls up to 4 motors
  • Automatic energy savings mode
  • Sleep and wake up function
  • Flying start protection
  • Flux breaking algorithm
  • Automatic carrier frequency change
  • Selectable V/F, Sensorless vector control
  • Built-in Modbus RTU communication
  • Optional motor circuit protection disconnect provides short circuit protection - No fuses required
  • UL Type 1 and 3R
  • UL Type 4 and 4X (contact factory)
  • Two or Three contactor bypass
  • AC cooled VFD options for extreme heat (consult factory)

Specs & Documents

Be the first to review this product

Availability: In stock

From: $1,000.00

To: $16,198.85

Price as configured: $0.00

Please select product spec for EMB-3 Contactor - Energy Management Bypass

Don't worry, you can change these later on.

A disconnect provides short circuit protection, and a means of disconnecting power to safely service the application. Disconnects can be locked/tagged out in the open (off) position to ensure the system isn’t energized during service.

Use a NEMA 1 enclosure when panels are installed in clean, indoor environment. NEMA 3R is a rainproof enclosure meant for outdoor installations.

Check the motor nameplate to find your motor's rated Horsepower

Enter single or three phase based on the incoming power distribution system.

Check the voltage on your motor nameplate. This should be consistent with the supply voltage from your power distribution system.

Check the motor nameplate to find the FLA of the motor. (SFA for submersible motors)

Price as configured: $0.00

  • Please select enter value.