P-Series Bypass 2C - 2 Contactor Bypass

P-Series Bypass 2C - 2 Contactor Bypass

P-Series Bypass 2C - 2 Contactor Bypass

  • 1-40HP (200~230VAC), 1-400HP (380~480), 1-125HP (525~600VAC), 3Ø
P-series VFD with a 2 contactor bypass, MMS disconnect, Hand/Off/Auto switch and VFD/Off/Bypass switch all in enclosure options for any environment
  • New Firmware makes setup a snap
  • Application based commissioning allows parameters to be automatically set based on industry standards
  • Applications: Basic, circulating pump, supply fan, exhaust fan or cooling tower
  • Selectable units include PSI, °F, °C, inWC, inM, Bar, mBar, Pa, kPa
  • Belt loss protection
  • Space Vector control for efficiency and long motor life
  • Cleaner sine wave as compared to typical V/Hz control. Motors run cooler and last longer
  • Advanced PID control (Pre-PID and Dual PID)
  • Maintain a constant control of pressure, flow or water level. This function includes Pre-PID, Sleep and Wake up and output inverse sub-functions
  • Dual PID for external PID control or cascade PID control
  • Multi-Motor
  • Multi-motor control function
  • Control up to 4 motors
  • Automatic energy savings mode
  • Adaptive flux control for varying loads (e.g. damper loading)
  • Sleep and wake up function
  • Increased energy savings by deactivating drive during low demand
  • Flying start protection
  • Prevents trips, rough starts, and drive damage from regenerative power from heavy fan inertia rotation
  • Built-in Modbus RTU communication
  • Optional: Profibus-DP, LonWorks, BACnet
  • Pre-heater function
  • Used to protect motor and inverter from damage when installed in damp location (e.g. green house).
  • Automatic carrier frequency change
  • Adjusts based on temperature for optimal operation
  • Selectable V/F, Sensorless vector control
  • Ideal for any control requirement
  • Long-life condenser & simple framework
  • Increased reliability
  • Line reactor
  • Output reactor/filter
  • UL Type 1 and 3R
  • UL Type 4 and 4X (contact factory)
  • Run pilot light (Green standard)
  • Bypass pilot light (Amber standard)
  • Fault pilot light (Red standard)
  • Door mounted speed potentiometer
  • Solid-state bypass overload
  • BACnet communications card
  • Lonworks communication card
  • N2 communications card
  • Drive auto bypass with relay

Product videos

Product videos
Play

Be the first to review this product

Availability: In stock

From: $1,000.00

To: $88,760.00

Price as configured: $0.00

Please select product spec for P-Series Bypass 2C - 2 Contactor Bypass

Don't worry, you can change these later on.

A disconnect provides short circuit protection, and a means of disconnecting power to safely service the application. Disconnects can be locked/tagged out in the open (off) position to ensure the system isn’t energized during service.

Use a NEMA 1 enclosure when panels are installed in clean, indoor environment. NEMA 3R is a rainproof enclosure meant for outdoor installations.

Check the motor nameplate to find your motor's rated Horsepower

Enter single or three phase based on the incoming power distribution system.

Check the voltage on your motor nameplate. This should be consistent with the supply voltage from your power distribution system.

Check the motor nameplate to find the FLA of the motor. (SFA for submersible motors)

  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes
  • No Yes

* Required Fields

Price as configured: $0.00

  • Please select enter value.